Medium RiskFDA Device
Medical Devices/Diagnostic Equipment

Shimadzu Autosamplers Recalled for Short Circuit and Testing Delay Risk

Agency Publication Date: November 26, 2024
Share:
Sign in to monitor this recall

Summary

Shimadzu Corp. has recalled 179 Autosamplers, including models SIL-20ACXR CL, SIL-20ACHT CL, and SIL-30AC CL, due to a design defect where condensation water can leak from a dehumidifier tray. This leakage can cause a short circuit on the main board, potentially charring internal cables or rusting the motor. If the device fails, it could cause significant delays in processing patient lab samples and delivering medical results.

Risk

A short circuit in the main board can lead to device failure or fire hazards, such as charred electrical cables. This malfunction creates a risk of delaying critical patient diagnostic tests, which may impact timely medical treatment.

What You Should Do

  1. This recall involves Shimadzu Autosampler models SIL-20ACXR CL, SIL-20ACHT CL, and SIL-30AC CL used for laboratory sample analysis.
  2. Identify if your device is affected by checking the model and serial number located on the device label. See the Affected Products section below for the full list of affected codes.
  3. Stop using the recalled product immediately.
  4. Contact Shimadzu Corp. Analytical & Measuring Instruments Div. or your local distributor to arrange for a return, replacement, or repair of the device.
  5. Call the FDA Consumer Complaint hotline at 1-888-463-6332 (1-888-INFO-FDA) for additional assistance.

Your Remedy Options

๐Ÿ“‹Other Action
How to: Stop using the recalled product. Contact the manufacturer or your distributor to arrange return, replacement, or correction.

Affected Products

Product: Shimadzu Autosampler (SIL-20ACXR CL)
Model / REF:
SIL-20ACXR CL
Serial Numbers (130):
L20995250001
L20995250002
L20995250003
L20995250004
L20995250005
L20995250006
L20995250007
L20995250008
L20995350010
L20995350011
L20995350012
L20995350013
L20995350014
L20995350015
L20995450016
L20995450017
L20995450018
L20995450019
L20995450020
L20995450021
L20995450022
L20995450023
L20995450024
L20995450025
L20995450026
L20995550027
L20995550028
L20995550029
L20995550030
L20995650031
L20995650032
L20995650033
L20995650034
L20995650035
L20995650036
L20995650037
L20995650038
L20995650039
L20995650040
L20995650041
L20995650042
L20995650043
L20995650044
L20995650045
L20995650046
L20995560001
L20995660002
L20995660003
L20995660004
L20995660005
UDI:
04540217420131
Product: Shimadzu Autosampler (SIL-20ACHT CL)
Model / REF:
SIL-20ACHT CL
Serial Numbers:
L20985350001
L20985450002
L20985750003
L20985750004
UDI:
04540217420124
Product: Shimadzu Autosampler (SIL-30AC CL)
Model / REF:
SIL-30AC CL
Serial Numbers:
L21005250001
L21005250002
L21005250003
L21005250004
L21005250005
L21005250006
L21005250007
L21005350008
L21005350009
L21005350010
L21005350011
L21005350012
L21005350013
L21005350014
L21005350015
L21005350016
L21005350017
L21005350018
L21005350019
L21005350020
L21005350021
L21005350022
L21005350023
L21005350024
L21005450025
L21005550026
L21005550027
L21005650028
L21005650029
L21005750030
L21005750031
L21005570001
L21005570002
L21005670003
L21005670004
L21005670005
L21005670006
L21005670007
L21005670008
L21005770009
L21005770010
L21005770011
L21005770012
L21005770013
L21005770014
UDI:
04540217420155

Additional Information

Agency: Food and Drug Administration (FDA)
Event ID: 95632
Status: Active
Manufacturer: Shimadzu Corp. Analytical & Measuring Instruments Div.
Sold By: Authorized distributors; Shimadzu Corporation direct sales
Manufactured In: Japan
Units Affected: 179
Distributed To: Mississippi, Arkansas, Texas, California, Massachusetts, Michigan, Florida, Oklahoma, Wisconsin, Indiana, Minnesota, Ohio, New Jersey, New York, Illinois, Kentucky, Nevada, Hawaii, South Dakota, Idaho, Utah, Washington, Missouri, Virginia, Georgia

Were You Affected by This Recall?

If you or a family member were harmed by this recalled product, you may have legal rights. Consider consulting a consumer protection attorney to understand your options for compensation.

Find an Attorney

This is general information, not legal advice. Go Backs is not a law firm and does not provide legal services.

AI-Enhanced Content: The summary, action steps, and risk assessment on this page were generated by AI from official government recall data to improve readability. This is not legal or medical advice. Always refer to the official agency sources below for authoritative information.

Sources: FDA iRES ยท Raw API Response

openFDA Disclaimer: This recall information is sourced from the openFDA API. Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. Refer to the openFDA terms of service for more information.